Creative Lighting logoCreative Lighting
Control Freak range · design toolBETA

Switchboard Designer

Tell us what you need to control and we'll lay out the eDIDIO controllers, UBi bus supplies and power supplies to run it — with an indicative parts list you can save as a PDF or send to us to confirm.

What are you controlling?

Enter your totals — we'll auto-lay-out a switchboard you can then fine-tune line by line.

≤55 suggested / line (64 max)
max 10 / line
×4 ch · 128 / line
512 / line
12 (4P) / 18 (6P)
max 4 / controller
LIDA D · 4 DALI addresses
DALI 0–10V · 2 addresses
eDIDIO S10 4P4 poles wide on the DIN rail · 2 lines · 12 switch inputs · 4 relay outputs
eDIDIO S10 6P6 poles wide · 4 lines · 18 switch inputs · 4 relay outputs · SD-card logging

Each line is DALI or DMX. We pick the model for you and you can change it afterwards. What the terms and order codes mean

Suggested switchboard

Editable — change any line and everything recalculates
Addressing: fitting = 1 DALI address, 0–10V = 2, LIDA D = 4; up to 64 per DALI line, ≤55 suggested; sensors use their own DALI addressing (≤10/line, not counted in the 64). Draws @ 24VDC: eDIDIO 100, UBi 250, LIDA D 50, 0–10V 100, DMX Splitter 100 mA. PSU shared per board up to HDR60 (2.0 A usable @ 80% target), then split per controller.

How the Switchboard Designer works

Enter how many DALI fittings, sensors, DMX fixtures, switch inputs and relay outputs your project has. The designer then:

Every line can be edited afterwards and everything recalculates. The result is indicative — send it to us and an engineer will confirm the specification and quote. For LED strip and fixtures, use the LED Driver Calculator.

Terms used

eDIDIO S10 4P / 6P
The two eDIDIO Series 10 controllers, named for their width on the DIN rail: the 4P is 4 poles wide and runs 2 lines with 12 switch inputs; the 6P is 6 poles wide and runs 4 lines with 18 switch inputs, plus an SD card for diagnostics and logging. Both take up to 4 relay outputs.
Order code
How the controller is ordered: model, then how many lines are DALI (D) and DMX (X). For example eDIDIO S10 6P 2D 1X is a 6P with 2 DALI lines and 1 DMX line.
Line
One DALI or DMX bus from the controller. A DALI line takes up to 64 devices (we suggest no more than 55, for headroom) plus up to 10 sensors; a DMX line carries 512 channels.
UBi
The UBi DALI bus power supply — one on every DALI line, 2 poles wide.
Pole
One standard DIN-rail module, 17.5 mm wide. Adding up the poles gives the length of DIN rail the switchboard needs.
HDR power supply & % load
The Meanwell HDR 24 V DIN supply that powers the controllers and modules. The % is how much of its rating the board draws; we keep it under 80%.
4-ch DALI relay · 2-ch 0–10V output · DMX Splitter
The LIDA D (4 DALI addresses), the DALI 0–10V converter (2 addresses) and the DMX Splitter (for more than 32 DMX devices on a line; no RDM).